Transonic Flowsensors

A range of Flowsensors are available to measure fluid flow in laboratory tubing.

Overview

Transonic Exclusivity

We are pleased to announce that ADInstruments are now the exclusive global distributors* of Transonic System's leading transit-time flow measurement solutions for life science research.

Learn more

*excl. Korea and Japan

Measure volume flow in laboratory tubing containing non-aerated liquids including water, saline, buffer solutions, blood, and other fluids, either by splicing into or clamping onto the tubing depending on the design. Tubing flowsensors provide reliable, stable measurements even under perturbed and non-steady flow conditions, for unparalleled accuracy and signature high resolution flow waveforms. For use with Tubing Flow System Options.

Precalibrated for easy, immediate use

Transonic flowsensors are precalibrated and ready for immediate use. Data is recorded with a corresponding flowmeter module and via an Instrument Interface and/or PowerLab into LabChart software, where flexible recording options and real-time calculations are available.

Product Configurations

Clamp-on Flowsensors (3-32mm outer diameter)

Product Code
PXL Series

PXL Series sensors “clamp-on” to most flexible laboratory and extracorporeal tubing. They provide total physical and electrical isolation is maintained between the sensor and the liquid, and thus ideal for quick, repeatable process testing that is applied to multiple circuits without flow interruption. Applications include artificial heart and VAD performance, medical device and pump engineering, manufacturing and compliance flow testing. Different options are available for tubing outer diameter measured in inches and mm. Each flowsensor is supplied standard with 2 m cable and a CC16 16-pin metal connector.

ME25PXN Inline Flowsensor (25mm inside diameter)

Product Code
ME25PXN

The ME25PXN Precision Inline Flowsensor mates easily with flexible laboratory tubing for volume flow measurement and can be calibrated for up to four fluid, temperature, and flow rate combinations. The flowsensor is supplied with a 1.85 m cable, and a CC16 or CP16 16-pin metal connector. 

Related

Research Applications

Langendorff
Cardiovascular Isolated Heart Systems
In Vitro Pharmacology + Isolated Tissue and Organs
Working Heart
Cardiovascular Isolated Heart Systems
In Vitro Pharmacology + Isolated Tissue and Organs
Tubing Flow
In Vitro Pharmacology + Isolated Tissue and Organs

Support

Support Articles

Our Support Articles contain answers to common questions, how-tos, solutions, and documentation.

Training and Workshops

Maximize time and resources with our customized training services delivered at your facility, on your equipment, on your terms.

See Training & Workshops

Details and Tech Specs

Technical

Product CodeProduct Name
ME-n-PXL-fld-tem-flowClamp-on PXL series Flowsensors (1/16” outside diameter increments)
ME-25-PXN-fld-tem-flowME25PXN Inline Flowsensor (25mm inside diameter)
Product CodeMin tubing size (mm)Max tubing size (mm)
ME2PXL

3.1

4.8
ME3PXL

4.8

6.4
ME4PXL

6.4

7.9
ME5PXL

7.9

ME6PXL

9.5

ME7PXL

11.1

ME8PXL

12.7

ME9PXL

14.3

ME10PXL

15.9

ME11PXL

17.5

ME12PXL

19.1

ME14PXL

22.2

ME16PXL

25.4

ME20PXL

31.8

n = size 

Flowsensor slot calibration options (up to four slots per flowsensor) include: 
fld (fluid) = KR for Krebs, BL for blood, H2O for water/saline, GL for 40% Glycerine/60% Water (by vol) 
tem (temperature  in degrees Celsius ) =  23 or 37 (standard temperatures) or TX (where X is specified between 19-40 for a custom temperature within this range)
flow = flow rate (SF for standard flow, LF for low flow or ULF ultra low flow)

Please note: 

  • Additional calibration charges may apply depending on required calibration configurations.
  • Tubing type and size (inside diameter x wall x outside diameter) must be additionally specified when ordering PXL flowsensors.  A tubing sample is required to be sent for the factory calibration process if non-stock tubing are used in the experiment. For example: 
    • Tygon ND 100-65 (1/4” inside diameter x 1/16” wall x 3/8” outside diameter) 
    • Tygon E-3603 (1/4” inside diameter x 1/16” wall x 3/8” outside diameter)

Pre-consultation is highly recommended before flowsensor selection. 

Product Codes

PXL Series
Clamp-on Flowsensors (3-32mm outer diameter)
ME25PXN
ME25PXN Inline Flowsensor (25mm inside diameter)
×
Ask a question

Have a question? Ask now

Ask a question